Abstract
Aim: To evaluate the changes in blood pressure, pulse rate and SpO2 pre during and post extraction procedure under local anesthesia.
Materials and Method:A total of 150 patients were included in the study. Pulse oximeter was placed to evaluate the parameters and changes were investigated before administering local anesthesia, during anesthesia, during extraction procedure and post extraction. Data was tabulated and statistical analysis was done using 20 SPSS software.
Results:Almost of the patients has increase in the systolic blood pressure and pulse rate during administration of local anesthesia and during extraction procedure. Very minimal change was observed in diastolic blood pressure and SpO2 levels.
Conclusion:Significant changes are noted in changes in systolic blood pressure and pulse rate pre administration of local anesthesia, during administration of local anesthesia, during extraction, and post extraction procedure. Diastolic blood pressure and SpO2 has no significant differences.
Keywords:Blood pressure, Pulse rate, SpO2, Dental extraction, Local anesthesia
How to cite : Tiwari R V, Sridhar M, Painam R T, Suvvari R K, Tiwari H, Evaluation of systolic and diastolic blood pressure, pulse rate and SPO2 levels pre and post dental extraction under local anesthesia. J Oral Med Oral Surg Oral Pathol Oral Radiol 2018;4(2):74-78
This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.